If you are getting 24 volts between G and C and the blower is not running then I would think that you either have a control board problem or a blower motor problem. If you aren’t getting 24 volts between G and C then you might have a thermostat problem, a thermostat wire problem or the low voltage fuse on the control board might be blown. ... the Snow Joe iON 24SB-XR (left) and the Ego SNT2102 Power+ Snow Blower (right). Clogged Fuel Filter. It is best to keep the blower running while the coil thaws so the blower air can keep the thawing water running down the coil and into the coils drain pan. Hi Lance! Leaf blower won't start. With the furnace on use a multimeter set to AC Volts, to test between terminals “R” and “C.” You should get a voltage reading of approximately 24 volts AC. According to the wiring diagram it is a 2 wire hookup, red and white. I could send you a pic of the wiring if that would help. I hope you can easily find and fix the problem. Right now the tstat green is hooked up to one side of the 24v relay, and the red (rh) is hooked up to the other side. I hope you can find the problem soon! Solution: Test to make sure you are getting 24 to 28 volts AC between the G (green) and C (com) terminals on you fan center or control board. To correct this problem, reconnect the terminals. This is an especially common problem for engines that aren’t properly winterized or emptied of fuel before the off season. If the blower fan works when you have the thermostat set to call for cooling, but does not work when you turn the fan on the thermostat to “Fan ON” then I would think that the thermostat is not making the connection to the G (green wire) when the thermostat is set to “Fan ON”. EGO 56V Blower KIT Includes 2.5Ah Battery & Charger is available at Total Tools. If you have a heating and cooling system where the fan is powered on through the W (heating wire) and Y (cooling wire) using a sequencer then you might not be able to use the thermostat. Easily adjust the variable-speed auger to control how far the snow is thrown, up to 35 ft. Check for these issues to get your gas powered blower going again.. 1. Something else? This sounds like you have a blower fan relay on the control board that is going out. Skip to main content. 1-800-269-2609 24/7. Yes, this could be either a thermostat problem or a control board problem. At next fall season start the blower will not run after choke is opened. A 2 speed, single phase 220v motor (low speed contact not wired into power). Continuously pulling on a recoil starter, when the engine is obviously not firing up, is going to make the situation worse. The new EGO POWER+ 2-Stage Snow Blower is the only cordless 2-stage snowblower that delivers the power and performance of gas without the noise, fuss and Our email address is: support@arnoldservice.com. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. I hope you have a great day! The new EGO POWER+ 2-Stage Snow Blower is the only cordless 2-stage snowblower that delivers the power and performance of gas without the noise, fuss and Whether you need furnace ignitors, AprilAire filters, EZ Flex filters, or another kind of HVAC merchandise, we want to serve you. If you have the fan center relay like we sell below the low voltage transformer is combined with the fan relay. As you know you would need 210 to 245 volts to two wires of the blower motor. The EGO 56V backpack blower comes in at the same speed, 145 mph, but with as much as 33% greater air volume. The YouTube videos in this post should show you how to determine if your control board is bad or if the motor is bad. View solutions. They could have loosened a connection up on your control board or thermostat with all the banging and vibration from hammering the roofing nails. Turn off the snow blower and disconnect the spark plug to make sure that the engine does not start accidentally while you're working on it. I did briefly rewire the motor to a. bypass the second 24v switch (which seems to be intermittent and funky), and b. connect to the proper side of the junction/terminal box, i.e. Is this an acc... How to Care for Your Electric Leaf Blower, 5 Advantages of Using an Electric Leaf Blower. Just replaced my Bryant 90 plus with a new circuit board and thermostat. Yes, that is weird about what is happening! If one is not working properly, the problem will be small and probably not difficult to locate. You could have one of the windings out in your blower motor. I registered the product immediately upon receipt. However, the blower motor runs just fine with the AC and the Heater. Without a voltmeter, it would just be a guess on any one of about 10 things. EGO POWER+ 21-inch 56V Lithium-Ion Cordless Snow Blower Kit with (2) 5.0Ah Batteries & 550W Charger (1219) $646 And. I believe I have covered the main problems. Hello Steve. Find EGO snow blowers at Lowe's today. I called EGO customer service. There are quiet a few variables that can occur to cause furnace problems. You will need a volt meter to test and see where your problem is. If you are looking for an HVAC products supplier that will treat you the way you should be treated, turn to us. Make sure you are getting 24 volts between the G and C (common) thermostat wires when you are having trouble with the blower coming on. If you want me to look up parts then please send me your air handler’s manufacturer’s model number to our email address: arnoldservice@gmail.com. On high, it kicked out a pretty solid 11.4 N. Hitting th… View and Download EGO SNT2100 operator's manual online. If one is not working properly, the problem will be small and probably not difficult to locate. If i switch the AC on then the blower motor works just fine. How to Protect Trees and Shrubs for Winter. En español Live Chat online. I bought Echo PB500T backpack blower and worked fine for fall and spring season. A technician changed the capacitor last time but this did not fixed the issue. If you can get 220 volts to the right two wires on your motor with a good capacitor then the motor should run.