Name 3 supervision circuits that require two separate and distinct signals. The completion of the final Schedule C form requires Mr. Jones to provide accurate accounting information from a personal recording standpoint as well as for... Use the fire extinguisher to control the fire (if can/ CAN BE CONTROLLED) Line-type heat detectors shall be located on the ceiling or on the side walls not moer than ----- from the ceiling. The pump running signal shall be -----, When appropriate in the overall fire safety plan, area smoke detectors located within a smoke compartment for open-area coverage may also be used to initiate control of smoke spread by operating (3) -----. Each ----- shall be programmed to call a second DACR line if the signal transmission sequence to the first line is unsuccessful. If a license has expired and the licensee desires to continue in the business for which the license was issued, he must apply to the state fire marshal for an original license. For the purpose of alarm annunciation, each floor of the building is not considered as a separate zone. What is the minimum number of adequate power supplies required for FA systems? A projected beam smoke detector is an example of a "line-type" detector. The applicant then must pass a written exam and pay the fee. Level NICET Testing and Study Guide 3. A distributor or installer must submit evidence of his ability to provide any needed repair or restoration of a system after being notified of a fire or fault in the system. A transmitter is a system component that provides as interface between SLCs, initiating device circuits, or control units and the transmission channel. T/F? junior_orozco. Suggested Reference material: NFPA 72, NFPA 70 , current OSHA materials, Management training books, and IBC, Write your scores as you receive them. OTHER SETS BY THIS … Only a ULC listed company . T/F? The responsibility for inspections, tests, and maintenance programs shall be assigned by the ----- to a designated person of authority. Section 4.4.1.5.1 (2) also provides for 4 hours of battery capacity. A licensed company that is providing service relating to the installation or maintenance of a fire system shall give ----- day's written notice to the owner, occupant, and AHJ before the licensed company discontinues service to the owner or occupant as appropriate. T/F? T/F? Any person who holds a license to service or install a FA system, must employ personnel who are qualified to install and perform service on FA systems. T/F? Smoke detectors shall be installed (3) -----, Household FA systems shall have 2 independent power sources consisting of a primary source that uses commercial light and power, and a secondary source consisting of -----. Each question comes with an answer and a short explanation which aids you in seeking further study information. If you change your address, in addition to notifying the State Fire Marshall you must pay the associated fee, what is it? If a fire system, device or component of a fire system does not have approval from UL or other approved testing lab, may the state fire marshal under certain situations approve its use? a telephone with access to a direct outside line. Vane type water flow switches are equipped with an adjusted delay device to compensate for water surges and pressure fluctuations, what is the max allowable delay time? In a combination system, a ----- signal shall take precedence or be clearly recognizable over any other signal. Smoke detectors in rooms with ceiling slopes greater than ----- rise per ----- horizontally shall be located at the high side of the room. .375 amps. key concepts: terms in this set (56) an approved central station company is one that has been issued a valid certificate from _____. The state fire marshal shall also require the applicant to -----. A ----- type detector is a device whose detecting element is concentrated at a particular location. FA boxes shall be visually inspected -----. Storage batteries shall ve located or enclosed so that the equipment of the signaling system including over current protective devices, will not be adversely affected by -----, Upon receipt of a trouble signal, the central station will, dispatch personnel to arrive within 4 hours to initiate maintenance if necessary. Work on the installation of any FA system cannot commence until the -----. A ----- is a radiant-energy sensing detector that detects the radiant energy emitted by a flame. In a protected premises FA system where fire pumps are required to be monitored by the FA installed in the building all signals other than "pump running" shall be supervisory signals. T/F? What is the time requirement by the State Fire Marshals office for a distributor or installer of protective signaling systems to respond for any needed service or restoration after being notified by the local fire department? D. An insurance company . The ----- is the root mean square A-weighted, sound pressure level measured over the period of time that any person is present, or a 24 hour period, whichever time is lesser. T/F? (3) -----, Failure of AC power supplying the radio equipment. A ----- can define an area from which a signal can be received, an area to which a signal can be sent, or an area in which a form of control can be executed. All points on the ceiling shall have a detector within a distance equal to ----- times the listed spacing. NFPA 72 recommends using a distance of ----- as a guide for spacing smoke detectors. Both sides of the auxiliary circuit shall be in the same conduit. Where publicly accessible FA boxes are installed, location -designating lights of distinctive color (blue) must be visible for at least ----- in all directions. (2). The location and proper use of all laboratory safety equipment (including eyewash, safety shower, fire extinguisher, and telephone.) A ----- is a device that is intended to detect flames and is designed to operate in environments where sunlight or other ambient lighting is assumed. T/F? Before installation of a FA system begins, detailed plans of the intended system must be submitted to whom for approval? Circuits between the protected premises and the supervising or subsidiary station, that are essential to the actuation or operation of devices initiating a signal indicative of fire, shall be so arranged that the occurrence of a ----- or single ground will not prevent transmission of an alarm. In a combination system, FA signals shall (3) -----. A device in which the detecting element is concentrated at a particular location is called a -----. General areas covered include inspection and testing procedures, periodicity, documentation, safety, and work management. Supervisory signals of a FA panel indicate what? Where changes to certain codes are adopted by the state fire marshal, they are listed in Chapter 477. T/F? A parallel telephone system is a telephone system in which an individually wired circuit is used for each box. T/F? InaKatt. Notify the state fire marshal in writing attesting that the original license was lost or destroyed. ------ is the maximum number of discrete elements of FA systems permitted to be used in a particular configuration. The visual representation of output data other than printed data is defined as -----, Parts of a circuit can be intentionally and permanently grounded to provide (3) -----. If a firm holding a FA license does not have an employee who holds a certificate of registration, that firm may continue to perform those services authorized by the license for up to 30 days while obtaining a qualified employee? Trouble signals and their restoration to normal shall be indicated within ----- seconds. T/F? Dust can clog a smoke alarm, so gently vacuum alarms every six months using a soft brush. This FA circuit does not use a monitoring current to monitor the integrity of the circuit. Use this on-line order form and your credit card to order a practice test from NICET. A means for turning off an activated alarm notification appliance shall be permitted only if -----, the means deactivates both the audible and the visible notification appliances simultaneously, If speakers are used to produce audible FA signals, trouble signals are required to be displayed when -----, an amplifier fails and the system is in alarm and operating on secondary power. What is a document that acknowledges the features of installation, operation, performance, service and equipment with representation by the property owner, system installer, system supplier, service organization, and the AHJ called? When a battery is used as a secondary power supply, it must have adequate capacity to operate the FA system for ----- under quiescent load, and at the end of that period, shall be capable of operating all alarm notification appliances for -----, A filter that has a bandwidth that comprises a frequency range of a factor of 2 1/3, the octave filter can be subdivided into three 1/3 octave bands called a -----, A single station alarm capable of being interconnected to one or more additional alarms so that the actuation of one causes the appropriate alarm signal to operate in all interconnected alarms is called -----. T/F? YOU MIGHT ALSO LIKE... TFM 11. Actuation of alarm notification appliances or emergency voice communications and annunciation at the protected premises shall occur within ----- after the activation of an initiating device. If an intermittent trouble signal is used, it shall sound at least every 10 seconds with a minimum duration of 1/2 second. (2) What does not? match. A license or certificate issued by the state fire marshal is not transferable and remains the property of the state fire marshal. A supervisory signal-initiating device for other than pressure tanks shall indicate a low-level condition. (3). The Fire Alarms practice tests reference NFPA 72 2007, NEC 2008, and IBC 2006. An area covered by notification appliances that are activated simultaneously is called a ------. The bottom of the box shall not be less than ----- and not more than ----- AFF. Cables used for interior installations shall comply with NFPA -----. To evaluate how much of the fire alarm industry you know. T/F? Which supervision circuit does not require 2 separate and distinct signals? Turn off the “MAX/MIN” setting on your meter. plenum. Each manual FA box shall be securely mounted. A. A distributor or installer of a protective signaling system must present the State Fire Marshall with evidence of the ability to respond for any needed repair and restoration within ----- hours of being notified by the fire department. ----- AFF and/or ----- from the ceiling, What is the correct mounting height and distance from the door for a manual station?----- AFF and ----- from the door. A ULC fire alarm certificate may issued by. The decision to designate a standard as a ----- is based on such factors as the size and scope of the document, its intended use and form of adoption and whether it contains substantial enforcement and administrative positions. ----- is a body or stream of gaseous material involved in the combustion process, emitting radiant energy. Any device used to sound a FA must be listed by UL for use as a fire alarm. Faults in other systems or components shall not affect the operation of the fire warning system. May an audible trouble signal be permitted to be common to several supervised circuits? 79 terms. Maintenance or installation of a protective signaling system can be done without license issued by the State Fire Marshal? It must be approved by ----. Records of all inspections, tests and maintenance shall be retained until the next test and for ----- thereafter. Nobody else has even helped 30 to pass in the last year! When the same sound is used for both supervisory and trouble signals, distinction between signals shall be by other appropriate means such as visible annunication. The wattage required for the load of the speaker as specified in subsection 1 of NAC 477.360. Who is responsible for insuring that the number and placement of loudspeakers installed in a combination paging alarm system meet the standards adopted by the state fire marshal? An office to which remote alarm and supervisory signaling devices are connected, and personnel are in attendance at all times, is defined as a fire station. Unless waived by the AHJ, the ----- of the building shall be designated at the proprietary supervising station or at the building protected. A means of conveying a number or channels over a single path, by modulating each channel on a different carrier frequency and demodulating at the receiving point to restore the signals to their original form, it called a -----, A path for voice or signal transmission utilizing modulation of light or alternating current within a frequency band is defined as -----, A FA system component with discrete identification that can have its status individually identified or that is used to individually control other functions is called a -----. The Water-Based Systems Layout practice tests reference NFPA 13 2007, NFPA 13D 2007, NFPA 13R 2007, NFPA 14 2007, and NFPA 20 2007. 23. Air duct detectors shall be securely installed in such a way as to obtain a representative sample of air system. The ----- shall provide for proper maintenance of the system. Where is it not required by laws or codes to install approved single and mutiple station smoke alarms? Enabling is allowed with password/limited access. Conventional FA initiating device circuits and notification device circuits fall under which classes (4)? A device designed to detect the presence of a fire signal and initiate action is called -----. If a system to detect, suppress, or protect against fire is reduced to less than 80% of its design standards by an action, whether malicious or not, by a holder of a license or certificate of registration. T/F? A 1/3 octave filter has a bandwidth that comprises a frequency range with a factor of 2 1/3. Are magnetic door holders, which allow doors to close upon loss of operating power, required to have an approved secondary power source? The signal from an automatic fire detection device selected for positive alarm sequence operation shall be acknowledged at the control unit by trained personnel within ----- of annunciation in order to initiate the alarm investigation phase, The circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked -----, A control valve shall be supervised to obtain a distinctive signal, indicating movement of the valve from its normal position. The evidence of that capability is subject to approval by the state fire marshal and must include a showing that the distributor or installer has (3) -----, The necessary equipment and qualified personnel. The tone generator used with a combination paging/alarm system must emit a unique tone distinctive in sound oscillation which -----, Combination paging alarm systems must be designed so that (3) ----, An annunciator panel is provided at the central station for control. Inspection and Testing of Fire Alarm Systems This certification program is for engineering technicians engaged in the performance, documentation, planning, and coordination of periodic inspection and testing of existing fire alarm systems and their components. An actuating device held or locked in the activation position shall prevent the activation and transmission of all other messages. A defined area within the protectged premises. F.A.C.T.S. All cables with taps and splices made shall be tested of insulation resistance when installed, but before connection to terminals. We have helped more than 4000 pass their state's licensing tests nationwide-- more than 300 in the past year. Equipment constructed and installed in conformity with NFPA-72 shall be listed for the purpose for which it is used. The audible signal shall not respond to faults on any other circuits that occur prior to the restoration of the silencing switch to its normal position. Standard NFPA-72 recognizes only those heat detectors with ratings of ----- feet or more. An audible and visual signal shall be activated on a FA system when the normal power supply is reduced by what percent? During the early 1980's the Canadian Fire Alarm Association established the Fire Alarm Technician Program, leading to personal registration as a fire alarm technician. josestretchnuts. The system shall automatically transmit a ----- signal within 15 minutes if a guard fails to actuate tour stations as scheduled. After installation, a visual inspection of all detectors shall be made to ensure that there are no changes that would effect ----- such as building modifications, occupancy hazards, and environmental effects. unique and distinctive enough to awaken a sleeping person. If a license or certificate of registration is lost or destroyed, a replacement may be obtained by what method? The max allowable time lapse from the initiation of a signal FA signal until it is recorded at the supervising station shall not exceed 90 seconds. Grant_Bradley7 TEACHER. The NFPA and IBC standards adopted by the state fire marshal are considered to be "minimum" standards. If so, what is that fee? One of the most critical factors of any FA system is the ----- the fire detecting devices. Oklahoma Burglar Fire Alarm license test study material package! Level I 29 CFR 1910 29 CFR 1926 FP HB V-1 FP … The licensee must report any changes of location to the state fire marshal within ----- after the change and pay a fee of -----. A permanent record of the time, date and location of a signals and restorations received and the action taken shall be maintained for at least ----- and shall be made available to the AHJ. Maintenance of Smoke Alarms and Carbon Monoxide Alarms Office of the Fire Marshal and Emergency Management Preface . A switch for silencing the alarm signal sounding appliances shall be permitted only if it is either (2) -----. 82 terms. Permanent records shall be maintained by the owner for ----- for examination by the AHJ. Where field conditions necessitate any substantial change from the approved plan, the corrected plan, showing the system as actually installed must be -----, submitted to the state fire marshal and the AHJ, All annunicator panels installed in the combination paging alarm system must (3) -----, use a common lock and key approved by the fire department. What is the listed spacing of a spot type smoke detector? 375 ma (milliamps) can also be expressed as _____. Local protective systems of the electrical type must test free of grounds. A coded alarm signal shall consist of not less than ----- complete rounds of the number transmitted. Where in NFPA-72 would you find the general information relating to mass notification systems? 130% B. T/F? T/F? Fire Alarm systems and other systems and equipment that are associated with FA systems shall be tested according to Table -----. Must this person also possess a state contractor's license pertinent to the work being performed? According to the regulations set forth by the State Fire Marshals office, the design and placement of all audio notification appliances integral to the operation of a protective signaling system and required standards is responsible by who? NFPA Fire Protection System, Inspection, test and maintenance manual. T/F? A ---- is a single station alarm capable of being interconnected to one or more additional alarms so that the actuation of one caused the appropriate alarm signal to operate in all interconnected alarms. The signal from an automatic fire detection device selected for positive alarm sequence operation shall be acknowledged at the control unit by trained personnel within ------ of annunciation in order to initiate the alarm investigation phase. A single fault on the SLC channel shall cause a trouble signal. Which type authorizes the holder to design the placement of, install, maintain and service FA systems? Application for renewal of a license or dertificate must be made annually. When any number of subsequent FA signals occur at any rate, they shall be recorded at a rate no slower than one every additional -----, When the runner is not in attendance at the proprietary supervising station, the runner shall establish two way communications with the station at intervals not exceeding -----, Automatic alarm initiating systems equipped with alarm verification features shall be permitted provided (4) -----, -The alarm verification feature is not initially enabled unless conditions or occupants are expected to cause nuisance alarms. The total sound pressure level produced by combining the ambient sound pressure level with all operating audible notification appliances shall not exceed ----- anywhere in the protected area (change from 120 dba in 2002 code). T/F? T/F? Room sizes and contours, airflow patterns, obstructions, and other characteristics of the ----- shall be taken into account. Let's take this up a knotch. T/F? d1st42. All FA systems and associated devices must be maintained and inspected in accordance with Table -----. Supervisory switches mounted on a sprinkler stand pipe must cause a supervisory signal at the panel within how many turns of the hand wheel? Reset the system. A distributor or installer of a protective signaling system must present the Atate Fire Marshal with evidence of his/her ability to respond for any needed repair and restoration within ----- hours of being notified by the fire department. On a sloping ceiling, detectors shall first be spaced and located within ----- feet of the peak, measured horizontally. What is the maximum time a license or certificate revocation can last? The wiring diagram that comes with the product will indicate this. This shall be permitted to be achieved by being (3) -----. Automatic Extinguishment is a function of a FA system. Prior to system maintenance or testing, the system certificate and the information regarding the system and system alterations, including -----, shall be made available to the service personnal by the owner or designated representative (3). The distributor or installer of a FA system must submit evidence of his capability to provide for any needed repair and restoration of a fire or fault in the system within ----- after being notified of a fire or fault in the system. Books I Used for Study . In a household FA system, all electrical systems designed to be installed by other than a qualified electrician shall be powered from a source not in excess of ----- volts that meets the requirements for power limited FA circuits. A ----- is a system component that provides an interface between signaling line circuits, initiating device circutis, or control units and the transmission channel. If ceiling heights allow, audible wall mounted devices shall have thier tops above the finished floor at heights of not less than ----- and below the finished ceiling at heights not less than -----. A fixed temperature heat detector which is color-coded green has a temperature classification of -----. Equipment shall be so designed that is shall be capable of performing its intended function at (3) -----, a relative humidity of 85 +/- 5% and an ambient temperature of 86F =/- 3F. T/F? A ----- is a device that will respond when its operating element becomes heated to a predetermined level. In areas that are not continuously occupied and are not fully sprinklered, automatic smoke detection, shall be provided at the location of each FA control unit as well as each ----- to provide notification of a fire at that location. T/F? For the purpose of alarm annunciation, each floor of a building shall be considered a separate zone. Before work can start on a FA systems installation, the plans must -----. If tone generating and amplifying equipment are enclosed as integral parts and service onlly a single listed loudspeaker,the failure of the tone generator or amplifier -----. If you do not renew your Certificate of Registration before the expiration date what happens? Here the induction machine is taken as example. Design the basic interface circuit (using an op amp) for a temperature sensor that covers a range of 0° to 70°C if the output of the sensor is 2 mV/1°C an... Next, the arrow icon was clicked to begin measuring temperatures. ... 7. To install any componet of a FA system, it must first be approved by UL or the State Fire Marshal. All means of interconnecting equipment, devices and appliances and wiring connections shall be ------ of the interconnecting conductors or equivalent path so that the occurrence of a single ground fault condition in the installation conductors or other signaling channels and their restoration to normal shall be automatically indicated within 200 seconds. T/F? According to the State Fire Marshal regulations, who is responsible for determining that the number and placement of loudspeakers as part of protective signaling systems meet the requirements of applicable standards? Visual and audible means to indicate a ----- % or greater reduction of normal power supply shall be provided. For active and two-way multiplex systems, the occurrence of ----- on the communication channel between a protected premises and the central station that will prevent the transmission of any status change signal shall automatically be indicated and recorded at the central station. NEC 760: Fire Alarm Systems Quiz Questions ) Search for: Related Pages. Does an applicant for a certification of registration need to pass a written exam? grounds. Does the state fire marshal have a minimum age requirement to hold a license or certification? All areas in a high-rise building protected by a FA system must be provided with sufficient notification devices to achieve ----- at any occupied space within the area protected. Detectors shall first be spaced and located within ----- of the peak, measured horizontally. The recording tag for a FA system must be punched in the approved manner to indicate the type of service performed on the system. A ----- is a SLC that uses the local leg of a public switched network as an active multiplex channel while simultaneously allowing that leg's use for normal telephone communications. Remember that NICET practice tests can only get you so far not only on the actual NICET exam but your future career in the fire alarm industry. T/F? NFPA 72 2013. To avoid nuisance alarms, the location of smoke detectors shall take into consideration normal sources of (4) ----- and electrical or mechanical influences, {"cdnAssetsUrl":"","site_dot_caption":"Cram.com","premium_user":false,"premium_set":false,"payreferer":"clone_set","payreferer_set_title":"Fire Alarm test","payreferer_url":"\/flashcards\/copy\/fire-alarm-test-2041728","isGuest":true,"ga_id":"UA-272909-1","facebook":{"clientId":"363499237066029","version":"v2.9","language":"en_US"}}. All points on a smooth ceiling shall have a detector within a distance equal to ----- times the listed spacing. test. When spot type smoke detectors are installed on a level ceiling with beam depths equal or greater than -----% of the ceiling height, and beam spacing equal or greater than -----% of the ceiling height, the detectors shall be located on the ceiling in each beam pocket. A ----- is an assembly that incorporates the detector, the control equipment, and the alarm-sounding device in one unit operated from a power supply either in the unit or obtained at the point of installation. A. The authority having jurisdiction. This Fire Alarm Technician / Fire Alarm Installer Certification program is for engineering technicians engaged in the performance, documentation, planning, and coordination of periodic inspection and testing of existing fire alarm systems and their components. This system may be used in whole or in part in common with another signaling system such as Voice Page or musical program system if all components are of a type approved by the state fire marshal and the non-emergency system doesn't degrade the alarm and paging functions of the system. Cram has partnered with the National Tutoring Association, Moistate Analysis: Proximate Analysis Of Mayonnaise, Three Criteria Of Business Entity Functions, Importance Of Safety Rules In The Laboratory Lab, Differences Between Machine And Induction Machine, Heat Transfer From Steam To Water Lab Report. In a household FA system, fixed temperature detectors or alarms shall have a temperature rating at least 25F above the normal ambient temperature and shall not be rated ----- higher than the max anticipated ambient temperature in the room or space where installed. Activation of a suppression system connected to a FA system must cause what type of signal? Cone type and Horn type loudspeakers must has a minimum rated wattage to provide the coverage specified in subsection 1 of NAC 477.360. Can a person holding a certificate of registration supervise the installation, maintenance or testing on a fire system without being under the employ of a licensee?
Colored Removable Labels,
Giselle: Act Ii,
Duromax E Vs Eh,
Songs With Lisa In The Lyrics,
Stamford Drug Bust,
Shaquil Barrett Salary,
Man Of Many Faces Quote,
Rent To Own Homes In Kingwood Tx,
Gta 5 Online Rocket Launcher,
How To Unlock Red Hood In Injustice 2,